Rm-materials-handling WIRE ROPE HOISTS Service Bedienungsanleitung Seite 40

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 130
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 39
R&M Materials Handling, Inc.
4501 Gateway Boulevard
Springfield, Ohio 45502
P.: (937) 328-5100
FAX: (937) 325-5319
40/130
R&M Materials Handling, Inc. reserves the right to alter or amend the above information without notice.
5.14.2 Assembly
1. Hoist limit switch
2. Connection-box cover
3. Fixing screws limit switch
Disassembly:
Switch OFF the power supply to the hoist.
Remove the connection-box cover (2).
Remove the wires from the limit switch.
Remove the fixing screws (3).
Extract the limit switch (1).
Re-assembly:
Fit the limit switch carefully in its place, so that the pinion fits into the gear-rim of the drum.
Tighten the fixing screws (3)
Re-connect the wires.
Switch ON the power supply to the hoist and check the proper functioning of the limit switch.
! In many cases it is necessary to re-adjust the limit switch. Be aware of incorrect settings
during testing the operation.
Seitenansicht 39