5.2.5 S7 Current Limit in traveling movement application
The frequency converter limits the maximum current. The limit settings for different currents are shown in the
following table. The limit is a percentage of the device’s nominal current.
Frequency converter
model
Nominal current [A]
003 2.4
006 5.6
Switch S7
Current
Limit [%]
003 [A]
006
[A]
Motor Example
-1 -2 -3 003 006
0 1 0 150 % (*) 3.6 7.7 2 x MF06MA200
2 x MF06LA200,
2 x MF06LA100,
4 x MF06MA200
1 1 1 130 % 3.1 6.6
1 1 0 120 % 2.9 6.1
0 0 0 110 % 2.6 5.6 MF06LA200
1 0 1 100 % 2.4 5.1
0 0 1 90 % 2.2 4.6 MF06MA200
2 x MF06MA200,
MF06LA200, MF06LA100
1 0 0 80 % 1.9 4.1
0 1 1 70 % 1.7 3.6 MF06MK200 35Hz MF06MA200
(*) Factory default setting.