Code Warning or Fault Possible cause Solution
7
Both drive commands on
/ parameter fault
Both drive commands are in the “on”
position
There is a short circuit in the pendant or
pendant cable
Parameters have been set wrong
Check the digital I/O cabling
Check the parameter settings (Switch
group S8 and S9)
To reset: set both drive commands to OFF
OR set correct values for the parameters,
turn the supply voltage off and restart after 1
min
other
fault
Other fault
Several reasons Replace the device